Rapid Pump & Meter Service Co., Inc.
285 Straight Street P.O. Box AY Paterson, NJ, 07509 USA
Phone:973.345.5600 • Fax: 973.345.0301
Email: info@servicer.com
• Website:
www.rapidservice.com
|

|
|
Item # V74X, Yaskawa AC MicroDrives
|
|
|
|
|
|
|
|
|
|
|
Power Supply ( 200 - 230 Vac, 3-Phase Input)
|
|
0.125 hp (0.8A) to 10 hp (33A)
|
|
|
Power Supply (200 - 230 Vac, 1-Phase Input)
|
|
0.125 hp (0.8A) to 3 hp (10.5A) by Derate
|
|
|
Power Supply (380 - 460 Vac, 3-Phase Input)
|
|
0.125 hp (0.8A) to 15 hp (21A)
|
|
|
Optional Enclosure
|
|
NEMA Type 4X (IP66)
|
|
|
Control Methods
|
|
Open Loop Vector (OLV) V/Hz
|
|
|
Speed Regulation
|
|
0.2% in OLV
|
|
|
Dynamic Braking Transistor
|
|
Standard
|
|
|
Dynamic Braking Capability
|
|
Up to 100%
|
|
|
Output Frequency Range
|
|
0.1 to 400 Hz
|
|
|
Constant Torque Turn Down
|
|
100:1 OLV mode 40:1 V/Hz Mode
|
|
|
Standard Keypad
|
|
LED with Pot; Isolated
|
|
|
Optional Keypad
|
|
With/without Pot, Remote
|
|
|
Copy Function Keypad
|
|
Standard
|
|
|
Digital Inputs
|
|
7 Multi-functional (24 vdc, isolated, PNP/NPN.)
|
|
|
Preset Speeds
|
|
16 plus Jog
|
|
|
Programmable Outputs Form C Relay
|
|
Quantity 1 plus 2 Open Collector
|
|
|
Digital Pulse Train Input
|
|
maximum 30 kHz
|
|
|
Flash ROM Software
|
|
CASE Software Solutions
|
|
|
Serial Interface
|
|
RS 422/485 Standard
|
|
|
Network Communication Option
|
|
Optional DeviceNet and Profibus
|
|
|
Separately Adjustable Accel/Decel Time
|
|
Maximum (2), 6000 s
|
|
|
PID
|
|
Standard
|
|
|
Additional Analog Input
|
|
Optional 0-10 volt or 4 - 20 ma, 10 bit
|
|
|
Bipolar Analog Input, Option
|
|
1,10-0-10 volt, 10 bit
|
|
|
Analog Proportional Output
|
|
1, 0-10 V or 4-20 mA, 10 Bit
|
|
|
115 Vac Logic Input
|
|
Optional PCB
|
|
|
Performance
|
|
Confirmed by load tests of competitor's microdrive products, the J7 and V7 truly demonstrate Best In Class performance characteristics such as acceleration capability, low frequency torque at 100% and 150% load, and response to step load changes (shock load and unload).
|
|
Starting Torque
|
|
The J7 produces excellent starting torque for many applications. If the absolute maximum starting torque is required, such as for loaded conveyors, centrifuge, or extruders, the V7 is the only logical choice. Both drives out-perform a popular competitor. Note that the competitor drive torque and current never stabilize.
|
|
Torque Response
|
|
The frequency regulator of the J7 and the V7 can be adjusted to provide the optimum torque response for any application. Some competitors models however, lack this capability to adjust torque response. This can result in less than optimum torque response in fan, pump mixer or conveyor applications.
|
|
|
Note
|
|
J7 and V7 were previously marketed as GPD 305 and GPD 315 drives.
|
|
|
|
|
- DIN Rail Mount: Optional
- Flat Plate Mounting (without heatsink): Model Available
- Motor Compatibility: Induction and Synchronous
- Torque Boost: Standard
- Analog Inputs: 1, 0-10 V or 4 - 20 mA, 10 Bit Resolution
- Input Bias and Gain Adjustments: Standard
- Simultaneous Use Network/Serial Communications and Keypad: Standard
- Preset Accel/Decel Ramps: 2 each
- Hold Command: Standard
- Frequency Reference Bias/Gain: Analog
- S-Curve Accel/Decel: 3 selectable times
- Overtorque Detection: Standard
- Stall Prevention: Standard
- Stopping Modes: Selectable Decel Ramp or Coast-to-Stop
- Speed Search: Standard
- MOP: Standard
- Carrier Frequency: 2.5 -10 kHz range; No Derate @ 10 kHz
- Cable Charging: Use 5 kHz Max Carrier Frequency for Distances > 100 Meters Between Inverter and Motor
- DC Braking: 100% for 0-25.5 sees, Current Based
- Common or Shared Bus Capability: Standard
- UL Listed Motor Overload: Standard
- UL, cUL, CE Mark- Standard
|
|
|
|
Food and Beverages
|
|
Yaskawa J7 and V7 drives support a diverse range of application and installation requirements including material handling, choppers shredders, mixers, small extruders, pumps and packaging. Superior acceleration, shock load/unload, and deceleration performance equate to trouble-free installation. These drives can be easily installed in all manufacturer's MCC packages. For washdown applications, special enclosures such as NEMA Type 4X can be provided to assure installation reliability. Network communication for the V7 includes DeviceNet Profibus and ControlNet.
|
|
Material Handling
|
|
These drives are ideal choices for palletizers conveyors and monorails. Best In Class performance during acceleration shock load/unload, and deceleration ensures reliable operation. V7 open loop vector control provides 40:1 constant torque turndown operation. Cascade control of multiple V7 conveyor drives can be accomplished via standard pulse train input and output. The V7 option, Bipolar Analog Input (+/-10 volt) allows forward/reverse operation directly through input command.
|
|
Automotive
|
|
Reliability and overall lowest cost of ownership are critical to the automotive industry. This criteria is surpassed with both the J7 and the V7. Options such as Bipolar Analog Input, full range network communication interfaces, 115 VAC input and modulated DB - all make the V7 the Best in Class choice for applications such as material handling conveyors and monorails.
|
|
Packaging
|
|
Either drive can be the right drive for the right cost for use in bottling lines, canning lines, wrapping machines, and bagging machines.
|
|
Fiber and Textile
|
|
Yaskawa AC drives have become the industry standard for performance and reliability for applications in Fiber and Textile. For metering pumps godet rolls, spinnerettes, and other applications in this industry, the V7 is the right drive. Reliable operation of synchronous motors is assured through proper regulator design with synchronous motor operation as a known design requirement. Frequency resolution of 0.01 Hz is standard. The drive can be connected in either common or shared bus configuration. Functions such as P-Jump/Traverse Dancer Control, and other application specific software requirements, are available in CASE Software for the V7. Network communication solutions ensure connectivity with major PLCs.
|
|
Fan and Pump
|
|
Over 50% of all ac drive applications are for fans or pumps. The standard feature set of both these drives support centrifugal and constant torque loads. Carrier frequency operation to 10 kHz is standard for quiet motor operation. High instantaneous overload capability (200% for 1 second) provides high breakaway torque for high static friction loads (positive displacement pumps). The ability to start into a spinning motor provides reliable application and installation performance. V7 NEMA Type 4X and other enclosure options are available. The V7 is Plenum Rated for HVAC applications where the drive must be mounted in the air stream/duct work.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|