Item # 4V10M6-23, Standard 4" Non-Clog Wastewater Pumps



Capacity : 715 gpm (45.1 lps)
Head : 59 ft (17.9 m)


Standard (4V) and Explosion-Proof (4VX) Construction

The 4V and 4VX (Explosion-proof) Submersible Wastewater Pumps pass a full 3" spherical solid and are the ideal choice when selecting a pump for your next application. Myers rounded port, 2-vane, enclosed impellers prevent solids from binding or clogging and offer high operating efficiencies to cut your pumping costs. The 4V series modified constant velocity volute case provides smooth operation over an extended portion of the performance curve for longer seal and bearing life. For use in municipal lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.

Advantages By Design
High efficiency hydraulic design cuts pumping costs and extends life of fluid end components.

  • Two-vane, rounded port, enclosed type impellers handle 3" solids with ease at high operating efficiencies.
  • Modified constant velocity volute offers quiet operation, low radial loads over extended portion of performance curve.

Durable motor will deliver many years of reliable service.

  • Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
  • Heat sensor thermostats imbedded in windings protect motor from overheat conditions.
  • Seal leak probe in seal chamber warns of moisture entry; helps prevent costly motor burnout.
  • Double tandem shaft seals prevent sewage from entering motor.
  • Power and control cables are double sealed with epoxy and compression grommet.

Available with optional UL approval for use in class 1, Group D hazardous locations (4VX only).






Specifications  · Construction Material  · Agency Approvals

Specifications

Head

59 ft
17.9
m

Solids Handling (Diameter)

3 in
76
mm

Liquids Handling

Effluent
Raw Unscreened Sewage

Storm Water

Intermittent Liquid Temperature

up to 140 ºF
up to 60
ºC

Winding Insulation Temperature. (Class F)

311 ºF
155
ºC

Motor Electrical Data1

1150 RPM
1-2 HP, 200/230V, 1Ø, 60 Hz and 208/230/460/575V
3Ø, 60 Hz

1750 RPM
3-5 HP, 230V, 1Ø, 60 Hz
3-10 HP, 200/230/460/575V
3Ø, 60 Hz

Acceptable pH Range

6 to 9

Specific Gravity

0.9 to 1.1

Viscosity

28 to 35 SSU

Horizontal Discharge Flanged Centerline

4 in. 125 lb
ANSI

101.6
mm

Power

1 hp

Voltage

230 V

Phase

3

Frequency

60 Hz

Start

20.7 A
8.3
kV·A

Run

6.4 A
1.8
kW
2.6
kV·A

NEC Code Letter

K

Service Factor

7.8 A
2.3
kW
1.2

Capacity

715 gpm
45.1
lps

Note

Consult factory for applications outside of these recommendations.
1 Single phase motors are capacitor start type. Myers control panels or capacitor kits are recommended for proper operation and warranty.


Construction Material

Motor Housing Material

Cast Iron, Class 30, ASTM A48

Seal Housing Material

Cast Iron, Class 30, ASTM A48

Volute Case Material

Cast Iron, Class 30, ASTM A48

Cord Cap Material

Cast Iron, Class 30, ASTM A48

Enclosed 2-Vane Impeller Material

Ductile Iron, Class 65, ASTM A536

Power Cord Material

25 ft. SOOW

Control Cord Material

25 ft. SOOW

Standard Double Tandem Mechanical Seal Material

Carbon & Ceramic, Type 21

Optional Double Tandem Mechanical Seal Material

Lower Tungsten, Carbide

Pump Shaft Material

416 SST

Motor Shaft Material

416 SST

Fasteners Material

300 series SST

Volute Wear Ring Material

Brass


Agency Approvals

Agency Approvals



 MORE IMAGES 

·  Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps-1

·  Dimensions (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)

·  Pump Performance-1 (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)

·  Motor Efficiencies and Power Factor-1 (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)

·  Pump Performance-2 (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)

·  Motor Efficiencies and Power Factor-2 (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)

·  Specifications (Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps)


 DOWNLOADS 

Myers® 4V and 4VX 4 in. Non-Clog Wastewater Pumps
(PDF, 610KB)


Request Quote