Item # 8VLX1000M4-53, Explosion-proof 8" Submersible Non-Clog Wastewater Pumps



Capacity : 3,875 gpm (14,667 lpm)
Head : 170 ft (50.8 m)


Standard (8VL) and Explosion-Proof (8VLX)

The Myers 8VL submersible non-clog Sewage Pumps are designed especially for high flow applications such as: Large Municipal lift stations, treatment plants, transfer stations and dewatering. A quick removal type rail system is available to simplify installation and maintenance. The 8VL's ability to handle solids up to 4 inches in diameter and 3 available motor speeds make it ideal for most high flow wastewater applications.

Advantages By Design
High efficiency hydraulic design cuts pumping costs and extends life of fluid end components.
  • Two-vane, rounded port impellers handle solids with ease at high operating efficiencies.
  • Modified, constant velocity volute offers quiet operation, low radial loads over extended portion of performance curve.
Durable motor will deliver many years of reliable service
  • Oil-filled motor and seal cavity for maximum heat dissipation and continuous bearing lubrication.
  • Heat sensor thermostats imbedded in windings protect motor from overheat conditions.
  • Seal leak probes warn of moisture entry: helps prevent costly motor burn-out.





Specifications  · Construction Material  · Agency Approvals

Specifications

Head

170 ft
51.8
m

Solids Handling (Diameter)

4 in
101.6
mm

Liquids Handling

Drain Water
Effluent

Raw Unscreened Sewage

Intermittent Liquid Temperature

up to 140 ºF
up to 60
ºC

Winding Insulation Temperature. (Class H)

356 ºF
180
ºC

Motor Electrical Data

1150 RPM: 30, 40, 50 hp, 3 ph
230, 460, 575 volts, 60 Hz
60 hp, 3 ph
460 & 575 volts, 60 Hz

1750 RPM: 75,100, 125 hp, 3 ph
460 & 575 volts, 60 Hz

870 RPM: 15, 20, 25 hp, 3 ph
208, 230, 460 & 575 volts, 60 Hz

Acceptable pH Range

6 to 9

Specific Gravity

0.9 to 1.1

Viscosity

28 to 35 SSU

Horizontal Discharge

8 in
203.2
mm

Speed

1750 rpm

Power

100 hp

Voltage

575 V

Phase

3

Frequency

60 Hz

Start

580 A
578
kV·A

Run

103.2 A
85.7
kW
103.0
kV·A

NEC Code Letter

G

Service Factor

124.0 A
103.0
kW
1.2

Capacity

3,875 gpm
14,667
lpm

Note

Consult factory for applications outside of these recommendations.
FM Class 1, Groups C & D


Construction Material

Motor Housing Material

Cast Iron, Class 30, ASTM A48

Seal Housing Material

Cast Iron, Class 30, ASTM A48

Volute Case Material

Cast Iron, Class 30, ASTM A48

Cord Cap Material

Cast Iron, Class 30, ASTM A48

Enclosed 2-Vane Impeller Material

Ductile Iron, Class 65, ASTM A536

Power Cord Material

25 ft. SOOW

Control Cord Material

25 ft. SOOW

Standard Double Tandem Mechanical Seal Material

Carbon & Ceramic

Optional Double Tandem Mechanical Seal Material

Lower Tungsten, Carbide

Pump Shaft Material

416 SST

Motor Shaft Material

416 SST

Fasteners Material

300 series SST

Case Wear Ring Materials

Bronze


Agency Approvals

Agency Approvals



 MORE IMAGES 

·  Dimensions (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Pump Performance-1750 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Motor Efficiencies and Power Factor-1750 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Pump Performance-870 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Motor Efficiencies and Power Factor-870 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Pump Performance-1150 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Motor Efficiencies and Power Factor-1150 (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)

·  Specifications (Myers® 8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps)


 DOWNLOADS 

8VL and 8VLX Series 8 in Submersible Non-Clog Wastewater Pumps
(PDF, 2144KB)