Blue Ribbon Controllers
blue-ribbon-controllers
Standard Features:
This controller is simple and inexpensive. It is so simple that even the least-trained operator can program six standard level setpoints for the control of the pumps -the on/off setpoints for the two pumps and the settings for the two alarms. That's it! Everything else is defaulted to a secure menu, pre-programmed for the customer. Everything is readily available in case you have to change range or decimal placement, suppress the zero, or turn off the alternation, etc.
The flexibility and variety of options in the secure menu will be applauded by engineers, while the operators will never have to learn those programming steps. Nothing could be easier! Untitled-22.jpg
Standard Features
This controller is versatile, simple, and inexpensive making it the ideal instrument for controlling dual pump lifting stations. Setpoints for ON/OFF and HI/LO alarms are easily set on the front panel. These same buttons also Enable/Disable pump alternation. Selectable time delay up to 60 seconds on power up for pump two prevents both pumps from starting at the same time and a large current draw. Alarms for pump seal failure and motor windings overheating are indicated by lights on the front panel. The dial can also display a runtime clock for each pump. An isolated 4-20 mA retransmission is standard. The front face is rated NEMA-4X for outdoor panel mounting. The BD-200 is also available with RS-232 or RS-485 protocol for connectivity with SCADA systems. Untitled-23.jpg
Thermoplastic NEMA 4X enclosure are constructed for indoor or outdoor. Untitled-aa.jpg
Standard Features
Blue Ribbon Bulldog BD100 Setpoint Pump Controllers
Dual setpoint controller that is easy to program. Controls submersible pumps in lift stations, and is designed to field calibrate the Birdcage Level Sensor.Standard Features:
- Control ON-OFF for two pumps
- Front-panel programming
- Analog output for run times.
- Secure menu for all other pre-set values
- 24 VDC power for sensor
- Accepts 4 - 20 mA or 1-5 VDC
- Nonvolatile memory, no batteries
- Alternation of pumps set as default
- Setpoints continuously displayed, along with current level readings
This controller is simple and inexpensive. It is so simple that even the least-trained operator can program six standard level setpoints for the control of the pumps -the on/off setpoints for the two pumps and the settings for the two alarms. That's it! Everything else is defaulted to a secure menu, pre-programmed for the customer. Everything is readily available in case you have to change range or decimal placement, suppress the zero, or turn off the alternation, etc.
The flexibility and variety of options in the secure menu will be applauded by engineers, while the operators will never have to learn those programming steps. Nothing could be easier! Untitled-22.jpg
Blue Ribbon Bulldog BD200 Setpoint Pump Controllers
Dual setpoint controller that is easy to program. Controls submersible pumps in lift stations, and is designed to field calibrate the Birdcage Level Sensor.Standard Features
- Selectable pump alternation when used with two pumps to minimize pump wear. With alternation "On", a seal failure or over-temperature condition will force the non-failed pump to lead status and stop alternation.
- Alarm light for seal failure when used with a sumersible pump that includes a moisture sensor.
- Alarm light for overheating when used with a pump that includes a thermostat. Pump is removed from service and can be brought back online manually or automatically when pump has cooled down.
- Runtime displayed by a front panel button.
- 24 VDC power for level transmitter
- 4 - 20 mA or voltage signal
- Nonvolatile memory, no batteries
- Test System function that simulates the process input to test programming or to insure the pumps are operating.
- User-selectable security lock-out of programming and/or setpoints.
This controller is versatile, simple, and inexpensive making it the ideal instrument for controlling dual pump lifting stations. Setpoints for ON/OFF and HI/LO alarms are easily set on the front panel. These same buttons also Enable/Disable pump alternation. Selectable time delay up to 60 seconds on power up for pump two prevents both pumps from starting at the same time and a large current draw. Alarms for pump seal failure and motor windings overheating are indicated by lights on the front panel. The dial can also display a runtime clock for each pump. An isolated 4-20 mA retransmission is standard. The front face is rated NEMA-4X for outdoor panel mounting. The BD-200 is also available with RS-232 or RS-485 protocol for connectivity with SCADA systems. Untitled-23.jpg
Blue Ribbon Bulldog BD300 Pump Controllers
(24) Features:- 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs
- Large Dual-Line 6-Digit Display, 0.60" & 0.46"
- NEMA4X, IP65 Front
- Universal 85-265 VAC, or 12/24 VDC Input Power Models
- Programmable Display & Function Keys
- 32-Point, Square Root, or Exponential Linearization
- Multi-Pump Alternation Control
- USB, RS-232, RS-485 Serial Communication Options
- Modbus® RTU Communication Protocol Standard
- Free BULLDOG Pro Software for Operation, Monitoring, and Programming
- Standard 1/8 DIN (45mm x 92mm)
- 4 Relays + Isolated 4-20 mA Output Options
- External 4-Relay & Digital I/O Expansion Modules
- Sunlight Readable Display Models - Optional
Thermoplastic NEMA 4X enclosure are constructed for indoor or outdoor. Untitled-aa.jpg
Blue Ribbon BB4000 4-Pump Controllers
(25) With the accuracy of pressure-sensing level transmitters and the simplicity of float inputs, the BB4000 is the ideal controller for your application. This quad pump controller is easily configured for either analog sensors of float discrete inputs.Standard Features
- Field configured for floats or analog sensor inputs, including 20VDC loop power.
- Optional 4 analog sensor inputs or 18 discrete (float switches).
- Alternates pumps and performs lag pump delay(s).
- Provides high and low alarms with full front panel.
- Adjustable parameter values.
- Optional VFD speed control output.
- Pump up (fill) or pump down (empty) control.
- 6 Amp pump relay outputs and alarm outputs.
- Display up to 255 feet.
- Full front panel setup for all control options and menu items.
- 120 VAC input power. Line rate and transient protection.
- Isolated and transient protected (4-20mA) analog level input.
- RS-232 serial port. Modbus Protocol. RTU or ASCII mode.
- First ON - First OFF, or First ON - Last OFF alternation.
- Alternator logic skips disabled pumps, remembers lead pump position during outage.
- Timed (1 minute) level simulation.
- Security code protected parameter setup.
- Status of discrete inputs may be viewed from front of control.
- Phoenix-style connectors used.
- Adjustable lag pump(s) delay.
- High and Low level alarm relays and alarm indication.
- Wet well level analog input zero and span adjustments.
- Alternation Schemes (menu selectable):
-Standard alternation
-Pump 1 always lead - stays ON with other pumps
-Pump 1 always lead - turns OFF with other pumps ON
-Split alternation - pumps 1 & 2 and pumps 3 & 4
-Fixed sequence - Pump always lead
-Stepped ON/OFF - only one Pump runs at a time - 18 discrete inputs, programmable for the following functions:
-Pump disable with HOA in OFF, or pump fault
-External alternator selector switch
-All pump disable (for connection to Phase Monitor)
-Limit number of pumps called while on emergency power
-alternation by External time clock
-Freeze wet well level during a bubbler tube purge
-Call Pump last
-Float switch backup
-A variety of telemetry functions