The answer is yes 
what is the question? VisaMastercardDiscover Visa, Mastercard, and
Discover Accepted
All Categories > Control Systems & Instruments > Yaskawa VFD Drives > Yaskawa Type 3R Packages > View Items  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Yaskawa Type 3R Packages

Check up to five results to perform an action.

The Type 3R Package is specifically designed for Yaskawa Variable Frequency Drives.

The Type 3R outdoor duty package is not just a "NEMA 3R" self-declared rating. Yaskawa went beyond its own stringent testing by asking Underwriters Laboratories Inc. (UL) to test and certify this package to meet UL 508A Type 3R for outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure.

The Type 3R Package is designed for applications such as Cooling Towers, Rooftop AHUs or Exhaust Fans, Irrigation Pumps and Water/Wastewater Pumps.

Designed to operate in ambient temperatures up to 104ºF (40ºC) without air conditioning with space for several commonly used options, makes this the preferred outdoor duty package for variable frequency drives. A standard option is available for ambient temperatures up to 122ºF (50ºC) without air conditioning.

There are many standard features of the Yaskawa Type 3R Package, such as:
  • The circled areas use the same filter media. This decreases the number of filter media part numbers which lowers cost of ownership. The filter media is easy to replace which lowers the overall maintenance cost of this outdoor duty package.
  • Dual ground lug - one lug for earth ground, one lug for utility ground.
  • Standard practice in the Yaskawa Type 3R Package is to provide filter media at exhaust ports. The filter media brackets include integral filter supports.




Compare Items
   
  Results 1 - 10 of 10 1 

Item #

Power

Height

Width

Depth

Power Supply

DD.AFD.198.01-208/240 10 hp
5
hp
7.5
hp
32 in 24 in 17.5 in 208/240 VAC
DD.AFD.199.01-208/240 15 hp
20
hp
40 in 32 in 17.5 in 208/240 VAC
DD.AFD.200.01-208/240 25 hp
30
hp
40
hp
46 in 42 in 17.5 in 208/240 VAC
DD.AFD.189.01-208/240 100 hp
50
hp
60
hp
75
hp
91 in 37 in 36 in 208/240 VAC
DD.AFD.190.01-208/240 125 hp
150
hp
91 in 74 in 36 in 208/240 VAC
DD.AFD.198.01-480 10 hp
15
hp
20
hp
5
hp
7.5
hp
32 in 24 in 17.5 in 480 VAC
DD.AFD.199.01-480 25 hp
30
hp
40
hp
50
hp
40 in 32 in 17.5 in 480 VAC
DD.AFD.200.01-480 100 hp
60
hp
75
hp
46 in 42 in 17.5 in 480 VAC
DD.AFD.189.01-480 125 hp
150
hp
200
hp
250
hp
91 in 37 in 36 in 480 VAC
DD.AFD.190.01-480 300 hp
350
hp
400
hp
450 hp (Bypass Configuration)

500 hp (Bypass Configuration)
91 in 74 in 36 in 480 VAC
  Results 1 - 10 of 10 1