Item # 3WHV10M4-03, Myers® 3WHV and V3WHV Series 3" Non-Clog Wastewater Pumps




Capacity : 400 gpm (25.24 lpm)
Head : 48 ft (14.6 m)


Horizontal and Vertical Discharge

The 3WHV and V3WHV series non-clog pumps are designed primarily for Commercial applications such as: Schools and Churches, industrial plants, shopping centers, apartments and condominiums, marinas, interstate rest stops, sewage collection systems, campgrounds, motels, restaurants, office and commercial buildings, state and federal parks, hospitals and nursing homes, dewatering, trailer parks and treatment plants. This pump can be installed on legs (vertical discharge) or with a quick-disconnect slide rail system. Its ability to handle 2:/2-inch spherical solids makes it ideal for most light to medium commercial installations.

Advantages By Design
High efficiency hydraulic design cuts pumping costs and extends life of fluid end components.
  • Two-vane rounded port impellers handle solids with ease at high operating efficiencies.
  • Modified constant velocity volute offers quiet operation, low radial loads over extended portion of performance curve.
Durable motor will deliver many years of reliable service.
  • Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
  • On winding overload (single phase only) protects motor from over current and heat conditions.



Specifications · Construction Material · Agency Approvals

Specifications

Head

48 ft
14.6 m

Liquids Handling

Raw Unscreened Sewage|Effluent|Storm Water

Intermittent Liquid Temperature

up to 140 ºF
up to 60 ºC

Winding Insulation Temperature. (Class B)

266 ºF
130 ºC

Motor Electrical Data1

1-5 HE 230V 1Ø, 60 Hz
1-5 HP 200/230/460/575V 3Ø, 60 Hz
1750 RPM

Acceptable pH Range

6 to 9

Specific Gravity

0.9 to 1.1

Viscosity

28 to 35 SSU

Discharge, Flanged Centerline. (Horizontal or Vertical)

3 in
76.2 mm

Minimum Sump Diameter (Duplex)

60 in
1.5 m

Power

1 hp

Voltage

200 V

Phase

3

Frequency

60 Hz

Start

36 A
12.5 kV·A

Run

5.4 A
1.3 kW
1.8 kV·A

NEC Code Letter

K

Service Factor

6.2 A
1.5 kW
1.2

Capacity

400 gpm
25.24 lpm

Note

Consult factory for applications outside of these recommendations
1 Single phase motors are capacitor start type. Myers control panels or capacitor kits are recommended for proper operation and warranty.


Construction Material

Motor Housing Material

Cast Iron, Class 30, ASTM A48

Seal Housing Material

Cast Iron, Class 30, ASTM A48

Volute Case Material

Cast Iron, Class 30, ASTM A48

Cord Cap Material

Cast Iron, Class 30, ASTM A48

Enclosed 2-Vane Impeller Material

Ductile Iron, Class 65

Power Cord Material

20 ft. SOOW

Control Cord Material

20 ft. SOOW

Standard Double Tandem Mechanical Seal Material

Carbon & Ceramic, Single, Type 21

Optional Double Tandem Mechanical Seal Material

Tungsten, Carbide

Pump Shaft Material

416 SST

Motor Shaft Material

416 SST

Fasteners Material

300 series SST


Agency Approvals

Agency Approvals

<!CSA>

larger image



 MORE IMAGES 

· Dimensions (Myers® 3WHV and V3WHV 3 in. Non-Clog Wastewater Pumps)

· Pump Performance (Myers® 3WHV and V3WHV 3 in. Non-Clog Wastewater Pumps)

· Meter Efficiencies and Power Factor (Myers® 3WHV and V3WHV 3 in. Non-Clog Wastewater Pumps)

· Specifications (Myers® 3WHV and V3WHV 3 in. Non-Clog Wastewater Pumps)


 DOWNLOADS 

 width= 3WHV and V3WHV 3 in. Non-Clog Wastewater Pumps
(PDF, 3600KB)


Request Information